KTI-Plersch Kältetechnik

Project inquiry

SAUTER Turbo

Turbo (hot water / hot air)

With the Sauter TURBO from KTI, cost awareness is paramount. The generation of hot air and hot water only requires one burner and works without loss of energy. The Sauter TURBO enables concrete production of up to 50m³ per hour at an outside temperature of -10 ° C. Any energy that is generated by the oil burner or gas burner goes directly as thermal energy either into the mixing water or as a hot gas / air mixture into the rock silos and sand silos. Therefore, there is no need for a chimney.

The concept of the TURBO is based on the long-term proven components of the Sauter heating systems. The best possible materials are used. These include the stainless steel heat exchanger, the well-insulated hot water tank in various sizes and the reliable burner technology with an output of 750 to just under 1,500 kW.

Depending on the version, the TURBO also offers the STEAM function for the quickest defrosting of the rock. A humidified exhaust-air mixture ensures maximum effectiveness at high air temperatures, which allows concrete production to start at short notice.

The Sauter Turbo is available in different versions, which essentially differ only in the distribution of energy for the production of hot water and hot air.

TURBO Splash

The TURBO Splash produces hot water (70%) and hot air (30%) with a water output of up to 22,500 l / h. Like all TURBOs, it does not require a chimney, as all of the energy supplied is used 100%.

Features KTI Sauter TURBO Splash:

Capacity:750 – 1500kW
Energy Distribution:70% water / 30% air
Water output (dT 40K):7.9 – 15.8 m³/h
Water output (dT 60K):5.3 – 10.5 m³/h
max. Water temperature:+ 85°C
Air volume flow:1200 – 1500 m³/h
Air outlet temperature:250°C
Burning medium:Oil, Gas
Execution:Containerized
Optional:oil tanks, additional hot water station

TURBO Dragon

The TURBO Dragon produces up to 3,500 m³ of steam plus hot water. The energy supplied is used 100% for steaming or for thawing of aggregates. Therefore, the TURBO Dragon does not need a separate chimney.

Features KTI Sauter TURBO Dragon:

Capacity:750 – 1500kW
Energy Distribution:25% water / 75% air
Water output (dT 40K):4 – 8 m³/h
Water output (dT 60K):2.6 – 5.3 m³/h
max. Water temperature:+ 85°C
Air volume flow:1200 – 1500 m³/h
Air outlet temperature:250°C
Burning medium:Oil, Gas
Execution:Containerized
Optional:oil tanks, additional hot water station

TURBO Switch

The new TURBO Switch combines the functions of the TURBO Splash and TURBO Dragon and produces either steam or hot water. Of course with 100% energy efficiency.

Features KTI Sauter TURBO Switch:

Capacity:750 – 1500kW
Energy Distribution (normal):70% water / 30% air
Energy Distribution (steaming):25% water / 75% air
Water output (dT 40K):11.2 – 22.5 m³/h
Water output (dT 60K):7.5 – 15 m³/h
max. Water temperature:+ 85°C
Air volume flow:1200 – 1500 m³/h
Air outlet temperature:250°C
Burning medium:Oil, Gas
Execution:Containerized